Galaxy are proud to be a Exclusive Distributor of Dalsan Corex A1

Galaxy are proud to be a Exclusive Distributor of Dalsan Corex A1
18 May 2020 master

Galaxy are proud to be a Exclusive Distributor of Dalsan Corex A1

Galaxy Insulation and Drylining are proud to be an Exclusive Distributor of COREX A1 Non-Combustible Gypsum Board. Primarily used for Passive Fire Protection of structural steel work, this product has great features and benefits including staple fix installation and no requirement for framing. Visit our website to find out more details or contact your local Galaxy branch, where our helpful team will be happy to supply or assist with this fantastic product!  Find some helpful details below or visit our Dalsan Corex A1 product page with detailed PDF specifications.

COREX A1

Classified reaction to fire of A1 non-combustible COREX A1 Gypsum based fire protection board has many tested applications.

Structural Steelwork

Primarily for use as Fire Protection encasement system for use around Structural Steel Work, it has been tested to EN13381-4 for up to EI 120 minutes

Has full Hp/A tables for the product on both British Steel sections and European sections for columns and beams.

The product does require any frame to install it as it fixes to itself – see video on the Galaxy Insulation Website – https://www.galaxyinsulation.co.uk/products/dalsan-corex-a1/

H1 rated – can be installed before building is watertight

Easy fix with staples

White appearance. however can easily decorated with direct applied paint (acrylic sealer required first) or plastered (apply suction coat first to aid adhesion)

App available to find the right product thickness for your application requirements and produces a report linked to ETA

 

Partitions

Tested to EN13501-2:2007 + A1:2009

Slim Construction at only 100mm thickness for 120 minutes EI

H1 rated – can be installed before building is watertight

White appearance. however can easily decorated with direct applied paint (acrylic sealer required first) or plastered (apply suction coat first to aid adhesion)

 

Ceilings

Tested to EN13501-2:2007 + A1:2009

For use on Concrete Beam and Aerated Slabs

120 minutes EI (used with min 14kg/m3 mineral wool)

H1 rated – can be installed before building is watertight

White appearance. however can easily decorated with direct applied paint (acrylic sealer required first) or plastered (apply suction coat first to aid adhesion)

 

Shaftwall

Tested to EN13501-2:2007 + A1:2009

Slim Construction at only 125mm thickness for EI 120 minutes (2x 25mm A1 Corex board), 115mm thickness for EI 90 minutes (2x 20mm A1 Corex board),  , 105mm for EI 60 minutes. (2x 15mm A1 Corex board)

Installation required from one side only

Fire performance from either direction

H1 rated – can be installed before building is watertight allowing shaftwall to be installed earlier in the building process.

White appearance. however can easily decorated with direct applied paint (acrylic sealer required first) or plastered (apply suction coat first to aid adhesion)

Recent News

We are now STA Members!
08 Jul 2020 master
We are now STA Members!

Galaxy Insulation and Dry Lining Ltd are proud to announce that we are now members of the Structural Timber Association (STA). We are leading the way in supporting the timber frame construction supply chain with our combination of products and technical services. Galaxy are already supplying many STA members with...

Galaxy shoots for the stars with ‘clear-sighted’ Mercedes-Benz Actros from Northside
06 Jul 2020 master
Galaxy shoots for the stars with ‘clear-sighted’ Mercedes-Benz Actros from Northside

Sheffield-based Galaxy Insulation & Dry Lining can see a clear road ahead as it emerges from the Covid-19 pandemic, thanks to the four-star Direct Vision Standard rating of its latest eight Mercedes-Benz Actros rigids. The 26-tonners were chosen specifically to work in London. They have ClassicSpace S-cabs with 320mm engine...

Experts In Fire Protection
08 Jun 2020 master
Experts In Fire Protection

Galaxy Fire Protection Specialists were asked to get involved at early stage with a Rainscreen contractor to help with identifying the most suitable ventilated Rainscreen fire barrier system for a 562 bed student accommodation in North London. Sheathed with Euroclass A1 Siniat Weather Defence, the project was to receive a...

Save Time - Call, Pay and Collect!
04 Jun 2020 master
Save Time - Call, Pay and Collect!

Galaxy continue to fully operate for collections and deliveries across all our branches. We have taken Health and Safety steps to ensure the welfare of our staff and customers is the upmost priority. We recommend calling your local branch and placing orders over the phone, to minimize the waiting times...

Meet our Interiors Specialist!
28 May 2020 master
Meet our Interiors Specialist!

At Galaxy Insulation and Drylining, we have a fantastic team of Interiors Specialists at our branches across the Country. With years of experience and knowledge of Interiors applications such as Medical, Educational, Catering, Hospitality, Leisure, Retail and Construction, our Interiors Specialists will ensure we can assist with all your enquiries....

We Stock Market Leading Suppliers