The Structural Timber Association has published Advice Note 19, Determining Timber Fractions — the first industry-agreed method for calculating how much timber is really in a timber frame wall. Galaxy Technical Services sat on the working sub-group and produced the benefits analysis at the heart of it. Here is what it says, and what it is worth to you.
Every U-value calculation for a timber frame wall has to deal with the timber itself. Studs, rails, noggins and soleplates conduct heat far more readily than the insulation around them, so the element is calculated as two heat flow paths — one through the insulation, one through the timber — combined as an area-weighted average.
The proportion of the wall occupied by that timber is the timber fraction. Under BR 443 (2019 Edition), most designers take the default: 15% for conventional studwork, or 12.5% where a tighter set of conditions is met.
The problem is that 15% is a convention, not a measurement. Real timber fractions in external walls range from roughly 8% to 21% depending on structural design, point loads, opening positions and building width. For a large number of well-designed panels the default is pessimistic — and specifiers end up buying insulation to compensate for timber that is not actually in the wall.
BR 443 has always allowed the alternative: calculate the fraction from as-designed manufacturing information. What the sector lacked was an agreed, auditable way of doing it — so calculated fractions were rarely used, and nobody could be confident two providers would reach the same answer.
Advice Note 19 closes that gap. Published in September 2026 and peer reviewed by the Building Research Establishment, it sets out a single method: what to measure, which timbers to count, which to leave out, and how to declare the result.
Our technical team was invited onto the STA’s Timber Fractions sub-group alongside timber frame manufacturers, insulation manufacturers and thermal design consultants, to shape the method and test it against real wall build-ups.
Our specific contribution was the benefits assessment — the modelling that answers the question every specifier asks next: what is this actually worth? We took three common timber frame constructions and calculated each one twice, at the 15% default and at a calculated 10% fraction, holding every other variable constant.
| Wall type | Insulation layer | Default 15% | Calculated 10% |
|---|---|---|---|
| Type A | 140mm mineral wool (λ = 0.032) | 0.194 W/m²K | 0.183 W/m²K |
| Type B | 120mm PIR (λ = 0.022) | 0.167 W/m²K | 0.154 W/m²K |
| Type C | 140mm mineral wool (0.040) + 25mm PIR (0.022) | 0.171 W/m²K | 0.166 W/m²K |
All build-ups: reflective breather membrane, 9mm OSB and 140mm studwork, reflective VCL, 15mm plasterboard, 50mm cavity and 102mm masonry cladding.
Type C is the one worth pausing on. Its improvement is the smallest, because the 25mm continuous PIR layer already interrupts the direct bridge through the stud — when the timber is no longer the weak point, reducing the timber fraction moves the number less. That is not a disappointing result; it is exactly why these gains need calculating rather than assuming, and why we would rather show you the wall where it barely pays than pretend it always does.
The advice note defines the timber fraction as bridged timber area divided by net wall area, expressed as a percentage. Gross wall area is taken from panel length and height, measured finished internal face to finished internal face; opening areas for windows and doors are subtracted to give net wall area.
The critical discipline is avoiding double counting. Timber already captured in a junction psi-value must not be counted again in the U-value:
| Counted in the timber fraction | Excluded (accounted for elsewhere) |
|---|---|
|
|
The worked examples in the note show how much the answer moves with building form:
| House type | BR 443 default | Calculated fraction |
|---|---|---|
| Detached | 15.00% | 9.58% |
| Semi-detached | 15.00% | 11.12% |
| Mid-terrace | 15.00% | 14.50% |
Illustrative examples from the advice note only. Every home varies in complexity, sizing, design features, number of apertures and structural principles — each design requires its own calculation.
The pattern is intuitive once you see it: the more external wall a dwelling has relative to its junctions and openings, the further the calculated fraction falls below the default. Detached homes gain most; mid-terrace units, with two party walls and proportionally more junction timber, gain least.
Calculated timber fractions are not free. They depend on as-designed timber frame manufacturing drawings, which means the process has to be sequenced properly:
One thing the note is firm about: the STA does not support timber fractions derived from a sampled, interpolated or weighted average across a range of building typologies. There are two supported routes — default, or calculated for that specific design. A figure borrowed from a similar plot is neither.
Two developments are worth watching. BRE has signalled a review of BR 443, and the STA intends to feed this advice note and the wider structural timber thermal details work into it. Separately, timber frame manufacturing software providers are investigating automating the calculation of as-designed timber fractions — the step that would take this from a project-by-project exercise to something the sector can adopt at scale. Until then, hand take-off and a self-declaration remain the route.
The direction of travel is clear either way. As heating moves to low-temperature electric systems that are less forgiving of poor fabric, the gap between designed and as-built thermal performance matters more, and calculations built on conventions rather than measurements will come under more scrutiny — not less.
Galaxy Technical Services supports specifiers, contractors and developers with U-value calculations, condensation risk assessments and thermal detailing across timber frame and masonry construction. If you want to know what a calculated timber fraction would do for a specific wall build-up or house type, send us the details and we will model it — including telling you honestly when it is not worth the effort.